OdaLog® Type L2

OdaLog<sup>®</sup> Type L2
The OdaLog® has been specifically designed to withstand harsh environments typically found in the Wastewater Industry.

The OdaLog® is primarily used by locating it at or close to the source of Hydrogen Sulphide emissions such as within sewerage pumping stations and receiving manholes.

Its purpose is to monitor gas levels to help control H2S gas in sewerage systems and treatment plants for later review and evaluation using OdaStat-G software.

Download brochure     Request quote

Key Features

  • Specially designed for harsh wastewater environments
  • Longer battery life (up to 12 months)
  • Simplifies record management
  • Real time data
  • Easy to read display
  • Faster downloading
  • Certified intrinsically safe
  • Two different types of sensors: LL (Long Term) Sensor or SL(Standard) Sensor

Typical Applications

  • Gas monitoring in manholes, drains and pits
  • Odour monitoring in sewer and streaming water
  • Ventilation pipes and rising mains
  • Inside sewer collection lines
  • Selected areas in treatment plants
  • Asset management and odour control

 

Model Gas Part Number Range Resolution Accuracy
(Full Scale)
Accuracy
(@ 20ppm gas, STP)
Long Term Logger (LL) H2S Hydrogen Sulphide ODALL-H2S-1000 0-1000 ppm 1 ppm 1% Full Scale ± 2ppm
ODALL-H2S-200 0-200 ppm 0.1 ppm 1% Full Scale
Standard Logger (SL) H2S Hydrogen Sulphide ODASL-H2S-2000 0-2000 ppm 1 ppm 2% Full Scale
ODASL-H2S-1000 0-1000 ppm 1 ppm 1% Full Scale
ODASL-H2S-200 0-200 ppm 0.1 ppm 1% Full Scale
ODASL-H2S-50 0-50 ppm 0.1 ppm 4% Full Scale
SL CO Carbon Monoxide ODASL-CO-1000 0-1000ppm 1 ppm 2% Full Scale
SL SO2 Sulphur Dioxide ODASL-SO2-50 0-50 ppm 0.5 ppm 10% Full Scale
SL NO Nitric Oxide ODASL-NO-100 0-100 ppm 1 ppm 2% Full Scale
SL NO2 Nitrogen Dioxide ODASL-NO2-50 0-50 ppm 0.1 ppm 4% Full Scale
SL Cl2 Chlorine ODASL-CL2-20 0-20 ppm 0.1 ppm 10% Full Scale
SL HCN Hydrogen Cyanide ODASL-HCN-30 0-30 ppm 0.2 ppm 6% Full Scale
SL NH2S Ammonia ODASL-NH3-100 0-100 ppm 1 ppm 10% Full Scale

NOTE: STP = Standard Temperature and Pressure: 20˚C (68˚F) @ absolute pressure 101.3 kPa (14.7 psi)